Enough ports does not mean enough PoE power.
Check the powered-port count, the individual port limit and the shared power budget separately. Passing one does not make the others pass.
Three limits, three questions
- Powered ports: Are enough ports actually PoE-capable? Do not count every Ethernet socket as a powered port; also allow for the network uplink.
- Per-port power: Can each connected device use the PoE type and power available on its assigned port?
- Shared budget: Can the switch supply the combined required allocation across every powered device at the same time?
Two manufacturer examples
Specifications checked October 17, 2026. Confirm the exact hardware revision, supplied power adapter and regional documentation before quoting.
| Switch | Ethernet / powered ports | Per-port output limit | Shared PoE budget |
|---|---|---|---|
| Ubiquiti USW-Lite-8-PoE | 8 / 4 PoE+ | 30 W at the power-sourcing equipment (PSE) | 52 W |
| TP-Link TL-SG1008P V7 | 8 / 4 PoE+ (ports 1–4) | 30 W | 64 W advertised* |
*TP-Link qualifies its budget as laboratory-based; actual availability depends on connected devices and environmental factors. Ubiquiti lists a 60 W adapter but only 52 W total PoE availability: adapter wattage is not the same as usable PoE budget.
Disclosed arithmetic examples—not tested installations
Assume the following figures are the required switch-side power allocations after the manufacturer's budgeting method, not camera-only consumption measurements.
- Four devices × 20 W = 80 W. Four powered ports and a 30 W port limit are sufficient for the count and individual loads, but 80 W exceeds both the 52 W and 64 W shared budgets.
- Eight devices × 6 W = 48 W. The total is below both advertised budgets, but eight directly powered devices cannot use only four PoE ports.
- One device requiring 40 W: a 30 W port is insufficient even if the shared budget has spare capacity.
Before approving the quote
Use manufacturer maximum requirements, including enabled IR, heaters or other accessories—not only daytime typical consumption. A device-side watt figure is not automatically the required switch-side allocation: cable losses, PoE class negotiation and the switch's allocation policy can matter. See the Axis explanation of maximum power and cable losses. Follow the exact device and switch documentation; do not treat all advertised watts as interchangeable.
CamPlan's numeric checks are planning aids, not electrical design approval or a compatibility guarantee. They do not automatically model negotiation, cable losses, startup behavior, temperature derating or every network topology. Passing arithmetic still requires installation and manufacturer verification.
Check ports and power in the free CCTV calculator
Then carry verified equipment and labor into Quote Builder. No automatic transfer or document extraction is implied.